logo
player background
live avator

5s
Total
0
Today
0
Total
0
Today
0
  • What would you like to know?
    Company Advantages Sample Service Certificates Logistics Service
Online Chat WhatsApp Inquiry
Auto
resolution switching...
Submission successful!
Zhenglan Cable Technology Co., Ltd
E-mail worldmarket@zhenglancable.com teren 86-371-61286031
Produkty
Produkty
Dom > Produkty > Low Smoke Zero Halogen Cables > IEC 60502-1 XLPE Insulated Cable

IEC 60502-1 XLPE Insulated Cable

Szczegóły produktu

Miejsce pochodzenia: Henan, Chiny

Nazwa handlowa: Zhenglan cable

Orzecznictwo: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007

Numer modelu: Kabel zasilający 0,6/1KV z trzema żyłami + 1 (nieopancerzony) w izolacji XLPE

Warunki płatności i wysyłki

Minimalne zamówienie: 300 metrów

Szczegóły pakowania: Bęben drewniany, bęben drewniany i stalowy, na życzenie klienta

Czas dostawy: 12 dni

Zasady płatności: Akredytywa, T/T,

Uzyskaj najlepszą cenę
Podkreślić:

fire resistant low smoke cables

,

low smoke halogen free cable

,

IEC 60502-1 XLPE Insulated Cable

Tworzywo:
99,99% miedzi beztlenowej
Aplikacja:
Elektrownia
Izolacja:
XLPE
Kolor osłony zewnętrznej:
Czarny lub dostosowany
Rdzeń:
3+1
Znak kablowy:
Drukowanie atramentu lub treść wytwarzania dostosowana
Długość bębna kablowego:
300 ~ 450 metrów na bęben
Charakteryzuje się:
Nieopancerzony
Tworzywo:
99,99% miedzi beztlenowej
Aplikacja:
Elektrownia
Izolacja:
XLPE
Kolor osłony zewnętrznej:
Czarny lub dostosowany
Rdzeń:
3+1
Znak kablowy:
Drukowanie atramentu lub treść wytwarzania dostosowana
Długość bębna kablowego:
300 ~ 450 metrów na bęben
Charakteryzuje się:
Nieopancerzony
IEC 60502-1 XLPE Insulated Cable

0.6/1KV Low Voltage Three+1 Cores Power Cable (Unarmoured) , XLPE Insulated Cable according to IEC 60502-1
 
Description:
0.6/1KV XLPE Insulated Cables (Unarmoured)

IEC60502,IEC60228,GB/T 12706.1-2008
CE,CCC,KEMA,ISO

 
Construction:
Conductors:Copper or Aluminium conductor, round standed or Shaped, Class 2 to IEC 60228, BS EN 60228. For smaller sizes, a solid round conductor, Class 1 as per IEC 60228, BS EN 60228 can also be supplied upon request.
 
Noted: Insulation color as per standards or customer requirement.
 
Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
 
Standard:
Basic design to IEC 60502-1, IEC 60228,BS EN 60228
China: GB/T 12706.2-2008
Other standards such as BS7870,DIN and ICEA upon request
 
Certificates:
CE, ROHS,KEMA and more others at request

 
Insulation:
XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
 
Colour Code Colour Code (1):
1 Core: Red or Black;   2 Cores: Red, Black;    3 Cores: Red, Yellow, Blue;   4 Cores: Red, Yellow, Blue, Black;     5 Cores: Red, Yellow, Blue, Black, Green;  Above 5 Cores: Black Cores with White numerals
 
Assembly /Inner Sheath:
Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted.

 
Armour:
Aluminum/Galvanized Steel Wires applied helically over the bedding as per IEC 60502 or as per BS 5467, BS 6346. Single core cables shall be Aluminium wire armour. Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502.
 
Outer Sheath:

Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.
Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE are available on request.
Fire Performance of Cable Sheaths:
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or other equivalent standards.
Cable Parameters:
Three+1 Cores Power Cable (Unarmoured)
 

Nominal
Cross
Section

Diameter of
Conductor
(Approx.)

Nominal
Insulation
Thickness

Nominal
PVC Sheath
Thickness

Overall
Diameter
(Approx.)

Weight
of Cable
(Approx.)

mm²(3)mm(1)mm(3)mm(1)mmmmmmKg/Km
3x 16/105.04.00.70.71.820.0825
3x 25/166.35.00.90.71.822.81235
3x 35/167.45.00.90.71.824.81565
3x 50/258.86.31.00.91.828.52220
3x 70/3510.67.41.10.91.932.02925
3x 95/5012.48.81.112.137.53525
3x120/7014.010.61.21.12.241.54940
3x150/7015.510.61.41.12.345.06250
3x185/9517.412.41.61.12.550.57450
3x240/12020.314.01.71.22.656.09500
3x300/15022.715.51.81.42.864.512100
3x400/18525.417.42.01.63.170.018900

 
IEC 60502-1 XLPE Insulated Cable 0
 
IEC 60502-1 XLPE Insulated Cable 1
 
Why Choose Zhenglan Cable:

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.
Kontaktuj się w każdej chwili
Zhenglan Cable Technology Co., Ltd
Adres::Floor 49, South Tower of Greenland Center, East Zhengzhou district, Zhengzhou, China
Faks: 86-371-61286032
Telefon:86-371-61286031
Send
Polityka prywatności | Chiny Dobra jakość Aluminum Power Cable Sprzedawca. 2019-2026 Zhenglan Cable Technology Co., Ltd . Wszelkie prawa zastrzeżone.